CRYO BOX XL™ details

Our Cryo Box XL is a multi-person cold chamber. In this cold chamber it is possible to treat several people at the same time. The Cryo Box XL is a hybrid device that is cooled with electricity and kept at the treatment temperature by liquid nitrogen.

  • Economic variant of indirect cooling technology using liquid electricity </ li> </ ul>
  • Rapid cooling
  • Low consumption of liquid nitrogen in cryotherapy
  • Low labor costs
  • Minimum construction costs for the installation of the cold chamber
  • Easy operation and contact with customer care of cryotherapy
  • Possibility of individual time and temperature control for each customer group in both chambers
    • Uniform representation of the temperature in question in the chambers </ li> </ ul>
    • Cold chamber 0104 is a certified medical device (certificate: EC92 / 42 / EEC) </ li>
      </ ul>

2–3 PEOPLE CAPACITY

Dimensions

width

depth

height

Weight

250 cm

270 cm

250 cm

1300 kg

Electrical parameters

230V / 1 / 50Hz / 16A

Technical information

Pre-cooling time 10 to 15 minutes.

Preparation chamber – adjustable temperatures from 0 to – 80 ° C.

Preparation chamber – adjustable times 1 to 3 min.

Main chamber – adjustable temperatures -100 to -150 ° C.

Main chamber – adjustable times 1 to 3 min.

Consumption 4.0 kw electricity / hour

Liquid nitrogen consumption

Consumption during pre-cooling: 45-50 kg

3-4 PEOPLE CAPACITY

Dimensions

width

depth

height

Weight

250 cm

300 cm

250 cm

1500 kg

Electrical parameters

230V / 1 / 50Hz / 16A

Technical information

Pre-cooling time 10 to 15 minutes.

Preparation chamber – adjustable temperatures from 0 to – 80 ° C.

Preparation chamber – adjustable times 1 to 3 min.

Main chamber – adjustable temperatures -100 to -150 ° C.

Main chamber – adjustable times 1 to 3 min.

Consumption 4.0 kw electricity / hour

Liquid nitrogen consumption

Consumption during pre-cooling: 50-55 kg

During cryotherapy about 3 kg / min

4-5 PEOPLE CAPACITY

Dimensions

width

depth

height

Weight

330 cm

300 cm

250 cm

2500 kg

Electrical parameters

230V / 1 / 50Hz / 16A

Technical information

Pre-cooling time 10 to 15 minutes.

Preparation chamber – adjustable temperatures from 0 to – 80 ° C.

Preparation chamber – adjustable times 1 to 3 min.

Main chamber – adjustable temperatures -100 to -150 ° C.

Main chamber – adjustable times 1 to 3 min.

Consumption 4.0 kw electricity / hour

Liquid nitrogen consumption

Consumption during pre-cooling: 65-75 kg

During cryotherapy about 4.5 kg / min

Installation requirements

  • The cold chamber should be in a room with dimensions of min. 5.5 x 4.5 x 3.5 m.
  • The room needs ventilation with (> 6 air changes per day)
  • It is not recommended to place the cryochamber in an environment with increased humidity, e.g. near swimming pools or whirlpools.
  • The cold chamber should be in a room with dimensions of min. 5.5 x 4.5 x 3.5 m.
  • The room needs ventilation with (> 6 air changes per day)
  • It is not recommended to place the cryochamber in an environment with increased humidity, e.g. near swimming pools or whirlpools.