CRYO BOX XL™ details
Our Cryo Box XL is a multi-person cold chamber. In this cold chamber it is possible to treat several people at the same time. The Cryo Box XL is a hybrid device that is cooled with electricity and kept at the treatment temperature by liquid nitrogen.
- Economic variant of indirect cooling technology using liquid electricity </ li> </ ul>
- Rapid cooling
- Low consumption of liquid nitrogen in cryotherapy
- Low labor costs
- Minimum construction costs for the installation of the cold chamber
- Easy operation and contact with customer care of cryotherapy
- Possibility of individual time and temperature control for each customer group in both chambers
- Uniform representation of the temperature in question in the chambers </ li> </ ul>
- Cold chamber 0104 is a certified medical device (certificate: EC92 / 42 / EEC) </ li>
</ ul>
2–3 PEOPLE CAPACITY
Dimensions
width
depth height Weight |
250 cm
270 cm 250 cm 1300 kg |
Electrical parameters
230V / 1 / 50Hz / 16A
Technical information
Pre-cooling time 10 to 15 minutes.
Preparation chamber – adjustable temperatures from 0 to – 80 ° C.
Preparation chamber – adjustable times 1 to 3 min.
Main chamber – adjustable temperatures -100 to -150 ° C.
Main chamber – adjustable times 1 to 3 min.
Consumption 4.0 kw electricity / hour
Liquid nitrogen consumption
Consumption during pre-cooling: 45-50 kg
3-4 PEOPLE CAPACITY
Dimensions
width
depth height Weight |
250 cm
300 cm 250 cm 1500 kg |
Electrical parameters
230V / 1 / 50Hz / 16A
Technical information
Pre-cooling time 10 to 15 minutes.
Preparation chamber – adjustable temperatures from 0 to – 80 ° C.
Preparation chamber – adjustable times 1 to 3 min.
Main chamber – adjustable temperatures -100 to -150 ° C.
Main chamber – adjustable times 1 to 3 min.
Consumption 4.0 kw electricity / hour
Liquid nitrogen consumption
Consumption during pre-cooling: 50-55 kg
During cryotherapy about 3 kg / min
4-5 PEOPLE CAPACITY
Dimensions
width
depth height Weight |
330 cm
300 cm 250 cm 2500 kg |
Electrical parameters
230V / 1 / 50Hz / 16A
Technical information
Pre-cooling time 10 to 15 minutes.
Preparation chamber – adjustable temperatures from 0 to – 80 ° C. Preparation chamber – adjustable times 1 to 3 min. Main chamber – adjustable temperatures -100 to -150 ° C. Main chamber – adjustable times 1 to 3 min. Consumption 4.0 kw electricity / hour |
Liquid nitrogen consumption
Consumption during pre-cooling: 65-75 kg
During cryotherapy about 4.5 kg / min
Installation requirements
- The cold chamber should be in a room with dimensions of min. 5.5 x 4.5 x 3.5 m.
- The room needs ventilation with (> 6 air changes per day)
- It is not recommended to place the cryochamber in an environment with increased humidity, e.g. near swimming pools or whirlpools.
- The cold chamber should be in a room with dimensions of min. 5.5 x 4.5 x 3.5 m.
- The room needs ventilation with (> 6 air changes per day)
- It is not recommended to place the cryochamber in an environment with increased humidity, e.g. near swimming pools or whirlpools.